Sunday, 5 November 2017

Surge Arrestor based on Quarter wave shorting stub

This technology is based on quarter wave transformation line.
The coaxial shorting stub applied for this purpose is short circuited at its end and its length is matched to the mid-band frequency of the operation band.It threby forms a band-pass filter.
Since lightning interference have a low frequency spectrum the shorting stub act as a short circuit, conducting the current to ground.

In regular operation, the RF signal reaches the entry of the shorting stub (shown here as point 1).
It then runs along the shorting stub up to the short (point 2). This corresponds to a 90° phase shift.
 At the short, the signal is reflected (point 2') –a sudden phase shift of 180° is created – and flows back to the start of the shorting stub (point 1'), where it arrives after another 90° phase shift.
As a result, the reflected signal is again in phase with the arriving signal. Therefore, the RF signal does not detect the short.
To go back to main page please click here


Surge Arrestor based on High Pass Filter


The concept behind this filter is that the low-frequency components of the lightning surge gets shunted to ground. As lightning energy has low frequency (lesser than 100KHz), these SA works as a high pass filter blocking surge energy.

To go back to main page please click here

Surge Arrestor based on GDT Principle



Depends on the working of Gas Discharge Tube.
A gas tube is an over voltage device that shunts current when a threshold voltage (the spark-over voltage) is reached. These are typically rated from 90V to 600V. It contains ionized gases.

When a voltage disturbance reaches the GDT sparkover value, the GDT practically shorts the line, diverting the surge current through the GDT to ground.

To go back to main page please click here

BASIC PRINCIPLE FOR RF SURGE ARRESTOR

There are basically three principles for coaxial SA devices.
Component based
1. Gas dischage tube (spark gap) Click here to know more about this principle
Filter based
2. High pass filter Click here to know more about this principle
3. Quarter wave shorting stub (Band pass filter) Click here to know more about this principle

Besides of these three, Designer uses Hybrid technolgy which combine two principles from above for its desired working.




RF Surge Arrestor

SA is a device to protect electrical equipment from over voltage transients caused by external (lightning) or internal (switching) events.

Concept behind Protection - Shunting
The goal of these devices is to protect the end product by shunting energy away. When the protection devices turn on, their impedance are reduced substantially. The circuit becomes current divider with most current going through the protection device.

Major Categories of RF Surge Protection Devices
1. Circuit Protection Components
Most common method of shunting transient energy is through circuit protection components such as Gas Tubes.

2. Filtering Components
Major method of shunting transient energy is through filter components such as inductors and capacitors.
Filter based RF SA's would have inductors and capacitors designed to handle kiloamp levels of surge.

To know on what principle these RF Surge Arrestor please click here.Basic Principle for RF Surge Arrestor

Sunday, 23 July 2017

Interview Questions For Quality Engineer/Manager

Q1: Tell me something about yourself or your brief introduction.

Q2: Tell me about your present company.

Q3: What are your roles/ responsibilities in your present organisation.

Q4: What are your day to day's activities in your present organisation.

Q5: 7 QC tools

Q6: Who is responsible for handling customer complaints in your organisation? if you are responsible, how you handled the customer complaints?

Q7: What is 8D?

Q8: Different types of root cause analysis. give some example of using these method in your organisation.

Q9: What are your departmental goals?

Q10: Internal rejection rate or Internal DPPM, How you calculate & monitored?

Q11: Difference between correction & corrective actions.

Q12: What is/ are your achievement in your career?

Sunday, 25 June 2017

Causes of Passive Intermodulation (PIM)

Ø Coaxial connectors - these connectors have joints between dissimilar metals and areas where oxidation can occur. Connectors that are assembled well using high quality components and water proofed well if they are to be used externally should last, but any connector will deteriorate with time. Connections made with poor connectors, or of the connectors have been assembled poorly will generate higher levels of PIM faster.
Ø Feeder lines - feeders such as coaxial feeders generate levels of passive intermodulation. The braid in the outer conductor provides many metallic interfaces in which passive intermodulation, PIM can be generated. Even if foil is used, there are interfaces between the layered construction of the foil wound round the dielectric. For applications where passive intermodulation is important coax with a good PIM performance can be bought. Some manufacturers may guarantee levels to below a given level, e.g. -140dBc, although at a cost.
Ø Joints where dissimilar metals meet and oxidation, etc. occurs converting the joint into an area that exhibits some diode effects.
Ø Dirty connections
Ø Loose connections and irregular contact areas, on a macroscopic or even a microscopic scale, can cause an inconsistent flow of current and generate inhomogeneous electromagnetic fields.
Ø General anodic effects
Ø The use of ferromagnetic metals, like iron, nickel and steel can give rise to passive intermodulation. These metals show magnetic hysteresis effects when energy is applied. This means that the resulting signal level is dependent, even to a small degree on input level. Hence this is a non-linear effect.
Ø Spark discharges can give rise to passive intermodulation. The spark will cause craters to be formed and some oxidation that will generate a diode effect. Sparks can result from poor connections or even the hot connection or disconnection of a connector.

Passive Intermodulation (PIM)

Passive intermodulation (PIM) is a form of intermodulation distortion that occurs in passive components such as antennas, cables, connectors, or duplexers with two or more high-power input signals. PIM in the transmission path degrades quality of the wireless communication system. Passive intermodulation occurs when two or more signals are present in a passive non-linear device or element. The signals will mix or multiply with each other to generate other signals that are related to the first ones.PIM can produce interference, and this can sometimes hide the wanted signal.

To know causes of PIM click on below link:
 Causes of Passive Intermodulation (PIM)

Sunday, 2 April 2017

Difference among Correction, Corrective & Preventive actions

Mostly, all the professionals come across these words specially Quality professionals . But sometimes we confused with the actual meaning of all these three words. I will try to explain all these words one by one with an example;

Correction

Suppose your smart phone touch screen gets damaged by falling on ground. What will you do first, of course you will get replaced your damaged touch screen by new & working touch screen. This is called correction. In short “ Correction is the action to eliminate non-conformity or correcting a occurred problem”.

Corrective Actions 

Now, when you replaced your touch screen of your smart phone what will you do next so that you don’t need to replace your touch screen again. You install a tempered glass on your smart phone touch screen. This is called corrective action as you are safe guarding your smart phone touch screen. In the event of falling of your smart phone, your touchscreen will be safe on the cost of tempered glass. In short “ Corrective action are taken on the root cause of the problem in such a way that it should not occur again”.

Preventive Action 

When you are installing tempered glass on your smart phone touch screen, you also installed tempered glass on your wife smart phone to avoid any future damage to her smart phone touch screen. This is called preventive action. “Preventive action is like failure mode effect analysis (FMEA) or risk management, where the non-conformity or problem have not actually occurred. We need to anticipate the risks that may occur & than think of actions that shall eliminate the cause of non-conformity”.  

I hope this will clears the concept of Correction, Corrective & Preventive actions. If you have any doubt or question please leave a question in comment box.

Saturday, 18 February 2017

TYPES OF SOLDER ANOMALIES/ DEFECTS

Following are the list of solder anomalies/ defects which we generally faced in soldering process:

1. Exposed Basis Metal
2. Pin Holes
3. Blow Holes
4. Non - wetting
5. Cold connection
6. Rosin Connection
7. Dewetting
8. Excess Solder
9. Less Solder
10. Solder Balls
11. Bridging
12. Solder Webbing/ Splashes
13. Disturbed Solder
14. Fractured Solder
15. Solder Projection

Sunday, 6 November 2016

SMT Process flow chart

Surface-mount technology (SMT) is a method for producing electronic circuits in which the components are mounted or placed directly onto the surface of printed circuit boards (PCBs). An electronic device so made is called a surface-mount device (SMD).
The flow chart for SMT is as follow:

 

Wednesday, 10 August 2016

Attenuation of Coaxial Cable

The power loss caused by a coax cable is referred to as attenuation. It is defined in terms of decibels per unit length, and at a given frequency. Obviously the longer the coax cable, the greater the loss, but it is also found that the loss is frequency dependent, broadly rising with frequency, although the actual level of loss is not linearly dependent upon the frequency.


Attenuation of coax-cables is described as the attenuation of the individual parts. Inner conductor, dielectric and outer conductor attenuation form the overall attenuation of the cable according equation [1].

αtot = α i+ α foam+ αo                                                                               [1]

The individual components are described with equation [2], [3]and [4].

Attenuation of inner conductor

α i             =          36.1*ki *√f / Zc*de                                             [2]

Attenuation of outer conductor

α o          =          36.1*ko *√f / Zc*De                                                          [3]

Attenuation of the dielectric layer

αfoam =     9.096 *√ εr* tan δ *f                                               [4]

α i        -           attenuation inner conductor [dB/100m]
α o        -           attenuation outer conductor [dB/100m]
αfoam     -           attenuation dielectric layer [dB/100m]
Zc         -           characteristic impedance [ohm]
f           -           frequency [MHz]
εr          -           dielectric constant
ki         -          shape factor inner conductor
ko         -           shape factor outer conductor
de         -          electrical equivalent inner diameter
De        -          electrical equivalent outer diameter

The electrical equivalent diameter considers the skin effect, which occurs on high frequency signals where the current tends to flow only in a very thin skin layer. The depth of penetration is given by following formula.

‘δ       =      15.9 / √(σ*f )

δ          -          conducting layer         [mm]
σ          -          conductivity                [m/Ω mm2]
f           -           frequency                    [kHz]

With above relation
de = di CU  – 2* δ
De = Do CUinner + 2* δ



Sunday, 7 August 2016

8D format example

                                               YOUR COMPANY NAME
                                        NON CONFORMANCE REPPORT
NCR NO.
REF. REPORT NO.
DATE:
PROCESS STAGE
DEPARTMENT/SUPPLIER
NCR RESPONSIBILITY:
REF. ITEM:
NON CONFORMITY OBSERVED
IMMEDIATE ACTION


DATE/DONE BY:
ROOT CAUSE ANALYSIS:


ROOT CAUSES:


DECISION:

DATE/DONE BY:
PLANNED ACTION


DATE/DONE BY:
IMPLEMENTED CORRECTIVE ACTION


DATE/DONE BY:
ACTION TO PREVENT OCCURRENCE


DATE/DONE BY:
VERIFICATION

CLOSURE


DATE/DONE BY:


ADDITIONAL DOCUMENTS ATTACHED:

For information on 8D methodology please click 8D Methodology

Wednesday, 10 February 2016

Knowledge Guru

Wednesday, 3 February 2016

REGRESSION ANALYSIS

In scientific research/industrial problem solving often a situation is encountered  where in  a number of variables are involved with possible interactions or relationship among themselves.
Regression analysis is a statistical technique for investigating and modeling relationship among these variables in such situations. As an example, consider the Current and Plating Thickness in electroplating. One may be interested to find out whether they are related and if so, what is the form of relationship. The relationship may be expressed in the form of an equation or model connecting one of the variables, known as the response or the dependant variable (denoted as Y) with one or more other variables known as explanatory or predictor or independent variables (denoted as X or X1, X2,X3 etc.).
The variables can be either quantitative or qualitative.  Examples of quantitative variables are measurable variables like hardness, tensile strength, diameter, width,  etc. Examples of qualitative variables are good/bad, defective/non-defective, religion, sex, region etc  

Applications of regression analysis are numerous and occurs almost every field, including engineering, quality control, physical and life sciences, economics, management, social sciences etc.

Sunday, 31 January 2016

DIFFERENCE BETWEEN ISO 9001:2008 & ISO 9001:2015 STANDARDS

Followings are the  difference between ISO 9001:2008 & ISO 9001:2015 standards:

ISO 9001:2008
ISO 9001:2015
0. Introduction
0. Introduction
1. Scope
1. Scope
2. Normative References
2. Normative References
3. Terms and Definitions
3. Terms and Definitions
4. Quality Management System
4. Context of the Organization
5. Management Responsibility
5. Leadership
6. Resource Management
6. Planning
7. Product Realization
7. Support
8. Measurement, Analysis and Improvement
 8. Operations
9. Performance Evaluations
10.Improvement

CLAUSES OF NEW ISO 9001:2015 STANDARD

Followings are the new clauses of new ISO 9001:2015 standard:

0. Introduction
1. Scope
2. Normative References
3. Terms and Definitions
4. Context of the Organization
5. Leadership
6. Planning
7. Support
 8. Operations
9. Performance Evaluations
10.Improvement

Thursday, 28 January 2016

INSERTION LOSS

Transmission feed line system performance plays an important
role in wireless network coverage. Insertion loss measurement
is one of the critical measurements used to analyze transmission
feed line installation and performance quality. 
In wireless communication systems, the transmit and receive
antennas are connected to the radio through coaxial cable
and/or waveguide transmission lines .
Insertion loss measures the energy absorbed by the transmission
line in the direction of the signal path in dB/meter or dB/feet.
Transmission line losses are dependent on cable type, operating
frequency and the length of the cable run. Insertion loss of a
cable varies with frequency; the higher the frequency, the
greater the loss.

In other words, insertion loss is the loss of signal power resulting from the insertion of a device in a transmission line or optical fiber and is usually expressed in decibels (dB).

If the power transmitted to the load before insertion is PT and the power received by the load after insertion is PR, then the insertion loss in dB is given by,
10 \log_{10} {P_\mathrm T \over P_\mathrm R}